JETNA-LP, 1000-5000 W, 3-phase, ultra-low profile, fanless

Powerful 3-phase-input Low Profile (LP) units of AEPS-GROUP series JETNA-LP with power factor correction ability are made for 3-phase mains 400 VAC (delta 323-440 VAC, 3 phases without N), 50 Hz. DC mains too can be connected, with any polarity and voltage of 390-620 VDC.

JETNA-LP series consists of JETNA1000-LP, JETNA2000-LP, JETNA3000-LP and JETNA5000-LP. The numbers state maximal output power in Watts, however to ensure long-term reliability the loading coefficient should be chosen from 0.7-0.8. Therefore, the series units are optimized for average power of 800, 1600, 2400 and 4000 W respectively.

Electrical features: all JETNA-LP units utilize output synchronous rectification up to 27 VDC output, which significantly increases their efficiency up to 94 %. The units include full set of service functions, up to providing external feedback (remote sense) function and active current sharing parallel operation. On request it’s possible to order models with high output voltages, up to 500 VDC.

Constructional features: series units JETNA-LP achieve a unique combination of compact design and high efficiency. This results in unprecedented power density of 35 to 42 W/inch3 in their respective power range. Aluminum or copper case base has stiffening ribs and also serves for conductive cooling. Considering that all components significant in weight are connected to the base and submerged in hardened heat-transferring potting – resistance to and durability against mechanical stress is unique. Unique property of the series is ultra-low-profile height (only 28.5 mm for JETNA1000-LP and 39 mm for JETNA5000-LP) and extreme temperature operating range of –60° C to +85° C (on request).

AEPS-GROUP JETNA-LP units are optimal to be utilized in application fields 1, 2, 3, 4, 5, 6, 7, 8, 9, 11 – for sealed and protected spaces as well as for aerial objects at heights up to 15 km in unsealed and unprotected spaces: planes, drones, helicopters, hot air balloons and gliding devices, meteoprobes. Also applied in all types of land transport – railway locomotives and wagons, cars, tracked vehicles. The units are also an optimal fit for telecom equipment, mining, supercomputers, radars and informational displays and screens, located in outdoors conditions. At the same time, JETNA-LP units operate in Arctic and Antarctica, in mountains at all heights and in cold or hot deserts etc.

To know more, read following essays: About input ranges, About efficiencyAbout planarity.

JETNA1000-LP

Output power up to 1000 W
Power density up to 36 W/In³
Efficiency up to 94 %
174х92х29 mm
Case operating temp. range up to -60° to +85° C on request
Product detail PDF Datasheet

JETNA2000-LP

Output power up to 2000 W
Power density up to 37 W/In³
Efficiency up to 94 %
210х116х37 mm
Case operating temp. range up to -60° to +85° C on request
Product detail PDF Datasheet

JETNA3000-LP

Output power up to 3000 W
Power density up to 37 W/In³
Efficiency up to 94 %
250х141х38 mm
Case operating temp. range up to -60° to +85° C on request
Product detail PDF Datasheet

JETNA5000-LP

Output power up to 5000 W
Power density up to 42 W/In³
Efficiency up to 94 %
300х170х39 mm
Case operating temp. range up to -60° to +85° C on request