AC/DC power supply platform · JETNAB-MIL

JETNAB-MIL-6000 - 6 kW continuous, in a case that still fits the compartment.

Three-phase in, 48 VDC out, with the cooling built into the box. It measures 400×350×133 mm, weighs under 20 kg, and ships as a sub-assembly rather than a finished enclosure, so the case, cover and front panel go on at your end.

Need more than 6 kW? The same platform has been taken to 7 kW, but that version we work out with your team before it ships. Here’s what that involves.

0 8000 W

Continuous output power

Standard 6,000 W Engineered 7,000 W

The platform

What you actually get

JETNAB-MIL-6000 is a 3-phase AC/DC power sub-assembly in a steel enclosure. The fans sit inside, pulling air in from the sides and pushing it out the back, so you don’t have to plan cooling around it. Several units can run in parallel for N+1 stacking, and they share load over a parallel bus, which means no external sharing hardware. The front panel carries digital readouts for output voltage and current plus a trimmer if you need to shift the output a little. When an application needs more than 6 kW, we build the 7 kW version on the same platform.

6,000 W continuous
48 VDC out, up to 125 A
93% typical efficiency at 70% load
Works from −40 to +65 °C ambient
400×350×133 mm, under 20 kg
Active parallel operation MIL-STD-461F CE101/CE102 MIL-STD-810F shock & vibration IEC/EN 60950-1 Unlimited output capacitance < 6 s startup
Side by side Full parameter list, 6 kW next to 7 kW
Parameter JETNAB-MIL-6000 JETNAB-MIL-7000
Output power6,000 W continuous7,000 W continuous
Output48 VDC @ 125.0 A300 VDC @ 23.3 A
Typ. efficiency @ 70% load93%93%
Input3-ph. 352–477 VAC, 47–63 Hz3-ph. 352–477 VAC, 47–63 Hz
Ambient operating temp.−40…+65 °C−40…+65 °C
CoolingInternal forced air - side intake, rear exhaustInternal forced air - side intake, rear exhaust
Enclosuresteel block, 400×350×133 mm, ≤20 kgsteel block, 400×350×133 mm, ≤20 kg
Output connectorM4 screw terminalsMolex 38720-3205, 5-pin
Output voltage adjustment±10% via front-panel trimmer±10% via front-panel trimmer
Ripple & noise (pk-pk)48 mVpp target (≈0.1%)300 mVpp max (≈0.1%)
Typ. MTBF30,000 h @ 0.7×Pout30,000 h @ 0.7×Pout
Engineering pathStandard configuration, repeatable to this specConfigured per application with AEPS engineering

Both versions ship as sub-assemblies, so the base case, cover, front panel, handles and thumb screws get fitted on your side during final assembly. One note on ripple: the 7 kW number is the released spec, the 6 kW one is still a qualification target.

Engineering review required

Why we don’t just sell the 7 kW version off the page

Going from 6000 W to 7000 W in the same case means roughly a sixth more heat to get rid of, through the same fans and the same vents. It works, but only if we know what the unit is going into. So every JETNAB-MIL-7000 gets worked out with your integration team first. In practice that comes down to four things.

  • 1Thermals, against your enclosureWe look at airflow, where the intake and exhaust actually end up, and the ambient range you really work in. Our own bench numbers aren’t enough here.
  • 2Protection thresholdsOver-current (110–125% Iout), the over-temperature trip and the "OK" signal logic all get re-checked at the new operating point.
  • 3MTBF for your conditionsThe 30,000 h figure assumes nominal conditions at 70% load. We re-run it against the ambient profile your installation will see.
  • 4Turn-on sequenceInput, output and trim sequencing agreed with your integrator before anything is powered up the first time.

Applications

Where these units usually end up

Ground & airborne systems
Radar & sensor arrays
Rail & transport platforms
Dense compute & supercomputing racks
High- & low-altitude unprotected compartments
Digital signage & industrial control in extreme climates

Control & monitoring

Five signals, and that’s the whole interface

Parallel operation, output-good, remote on/off and the voltage trim. That’s everything your control harness has to deal with. If you move to the 7 kW version later the input and service connectors stay the same, and the output connector is the only thing that changes.

PAR
Parallel-operation bus - tie together across all stacked units
+OK / −OK
Output-good status, open-collector - low while output and thermals are within range
+RON / −RON
Remote ON - short together to enable the output
ADJ (front panel)
Output-voltage trim, ±10%
+OUT / −OUT
M4 screw terminals